The honeywell aquastat controller is an immersiontype device for limiting or regulating the temperature of liquids in boilers, storage tanks and other applications where temperature control is required. They provide spdt switching for threewire applications. Honeywell l6006 and l6007 aquastat controllers, installation instructions for the trained service technician, these controls combine low or high limit and circulator control, with or without an immersion well depending on the control model a,b. Installation honeywell l6006 user manual page 8 of 20. Tr temperature ad adjustable differential direct mount 100f240ftrad 5f30f desc direct mount temp. L6006 and l6007 aquastat controllers installation instructions for the trained service technician. I cant find my honeywell book, but i looked in sid harveys. Honeywell home aquastat controllerl4006a1967u the home. Product data and specificationsproduct data for l4006, l4007, l4008, l6006, l6007, l6008 aquastat controllers english maintenanceproduct reference materials2015 residential combustion application selection and crossreference guide.

Features l l4006, 7, and 8 provide spst switching for high or low limit or circulator control. Immersion well must snugly fit sensing element and bulb must rest against bottom of well. Honeywell l6006a1145 highlow limitcirculator aquastat with. Honeywell l6006a aquastat aquastat was removed from a working system. The aquastat uses an immersion system that has two switches controlling the high and low temperature limits on the heater.

The reset button keeps tripping but the answered by a verified hvac technician we use cookies to give you the best possible experience on our website. Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. How do i know a honeywell aquastat manual reset red button type is bad. Honeywell l6006a1145 homeresideo aquastat controller 100. L6007a installing immersion well models l4006a,b,e,g. Boilers usually have tappings that allow the well to be mounted horizontally so boiler water of average temperature can circulate freely. Aquastat relay choices from grainger operate with a 24vac thermostat or a 750mv thermostat, depending on the model. There are separate adjustments and a calibrated dial for each switch. Buy honeywell l6006c1018 high or low limit circulator aquastat, 65200f range, 530f differential, stop factoryset at 200f, surface mount, no well. We have the honeywell aquastat l6006a you need to get the job done right. Feb 23, 2011 how do i know a honeywell aquastat manual reset red button type is bad. Set to 180 it would break when the water temp hits 180 and make when the water temp drops below the differential setting. Honeywell technical support information, product brochures and more.

Settings for honeywell l6006c with hydroair we have a hydroair blower which has a honeywell l6006c 1018 aquatstat on the supply pipe at the coil. Wired whites together and put two black wires to the two terminals on the switch. Totally enclosed micro switch snapacting switches operate on temperature rise to setpoint. Totally enclosed micro switch snapacting switches operate on temperature rise to set point. View and download honeywell aquastat l4006a installation instructions manual online. Summary of contents of user manual for honeywell l6006. Jul 02, 2017 highlow limit installation of controls heatinc100. It keeps the fan blower from running until the water heats to a set temp. Electronic oil aquastat electronically monitors and controls circulatory, burner, and boiler temperatures and provides electronic temperature sensing in an oilfired hydronics heating appliance not included.

L6006,7,8 aquastat controllers product data features for vertical mounting and l4006, 7, and 8 provide spst switching for. In the run mode, the aquastat will flash bt boiler temp followed by the temperature i. How to program the triple aquastat and set up the high limit aqastat. Terminals on these aquastat relays are approved only for copper wire. Honeywell l6006 series aquastat for highlowcirculator applications with 530f adjustable differential and 100f240f temperature range. Controller application the honeywell super tradeline. This remote bulb type controller regulates the temperature in boilers and tanks. If used, well must snugly fit sensing bulb for best. Range 100 degrees to 240 degrees f, differential manual reset, 8, 48, 30. It provides spdt switching for high limit, low limit or circulator control. Honeywell l4006e1067 high limit aquastat breaks on rise, 270f range, 250f factory stop, less well overview.

If the old immersion well appears suitable, and if the adapter clamp on the aquastat controller fits the old well spud, this well does not need to be replaced. The l6006a is designed for horizontal or vertical insertionmounting using an immersion well not included. L6006 aquastat controller aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell home aquastat controllerl4006a1967u the home depot.

Settings for honeywell l6006c with hydroair heating help. Bend the tubing, if necessary, to hold bulb against the bottom of the well. L6007a on an existing installation, shut off the power and remove the old control. Single and multifunction aquastat controllers industrial. To read aquastat settings, press the i key to read the parameter of interest. Honeywells l4006 are used in applications that utilize the existing wells.

Application these aquastat controllers operate in response to temperature changes in hydronic heating systems. Choose from immersion controllers, universal electronic, multizone and dual aquastat controllers with a variety of temperature ranges and differentials and spst or spdt switching types. Currently, our boiler operating temp is about 180 degrees. Honeywell l6007, l6008, l6006, l4007, l4008 user manual. The honeywell aquastat is a controller designed for boiler water control in heating systems that are either oil or gas fired. For example, press i hl high limit is displayed, followed by a threedigit number, i. Honeywell l6008a1192 120v line voltage aquastat controller. Honeywell 120 volt, line voltage electric aquastat controller with a 100240f operating range adjustable 530f differential and 5 capillary. If the system is filled, drain the system to a point below the boiler tapping, or to wherever the sensing bulb is to be installed.

The aquastat controller can be remotely mounted either vertically on a wall or panel, or directly on the boiler, tank, or vessel. Single and multifunction aquastat controllers l4006, l6006 aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. How do i know a honeywell aquastat manual reset red button. View and download honeywell aquastat l8124a installation instructions manual online. Works with circulator, low and highlimit or unit heat control. The honeywell aquastat controller is a strap on type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. L6006a controller operates in response to temperature changes in hydronic heating systems. For example, press i hl high limit is displayed, followed by a. Regulates the temperature of liquids in boilers and storage tanks. Honeywell l6006a aquastat controller installation instructions, also available at. The l6006a,b, and l6007a combine low or high limit. It has an external adjustment screw that permits easy setting and an immersion element that can be inserted horizontally or vertically. Dont know where to put wire coming in and wire going to circulator.